How to change modes on a Pulse R.
The Pulse R™ is configured for the desired operating mode at the factory and should only be changed if directed to do so by a Unist representative.
To change modes, press and hold both the UP and DOWN buttons while turning on power to the Pulse R™. Continue holding buttons for 2 seconds until the mode number with a period before it is displayed.

Use the UP and DOWN buttons to select the desired mode. To confirm selection, press and hold the UP and DOWN buttons for 2 seconds. After 2 seconds, the display will show the set point for the selected mode.
When changing to modes 3 or 4, the system will display the shot delivery rate (in cycles per minute) after pressing and holding the up/down buttons for 2 seconds. The user can then change the shot delivery rate by pressing the up or down buttons. Pressing and holding the up/down buttons for 2 seconds will then save the mode and the desired cycle rate.