Pulse R Display Units.

2022-12-29
 


The Pulse R has 5 different modes that it can operate in, the display has different meanings/units depending on which mode it is in. 

In modes 1 & 2, the display reads out the number of cycles per minute.

In mode 3, the display reads out the number of shots delivered upon power up.

In mode 4, the display reads out the number of shots delivered after an input signal is received.

Note: In modes 3 & 4, the first character displayed is an “S” for shot mode. When changing to modes 3 or 4, the system will display the shot delivery rate in cycles per minute. This only occurs when you first change to mode 3 or 4. 

In mode 5, there are two values that could potentially be displayed. If the up button is pressed, the display will flash “Cnt” and then display a number, this number represents the number of inputs to count before turning on the valve. If the down button is pressed, the display will flash “dUr” and then display the valve on time in seconds.